Q-Series 1 Way Blow

Q-Series
1 Way Blow

These units are ideal for densely populated spaces such as classrooms, lecture halls, open floor plan offices and spaces with high ceilings.

1-Way Blow Q-series Models with Code Compliant Drain Pans:

  • 2’x4’ QLS
  • 2’x4’ QHS
  • 2’X4’ QLU
  • 1’x4’ QLW
  • 2’x2’ QM1
  • 2’X2’ Q1 & Q1-L
  • QWV

 

2’x4’ QLS

  • Provides Sensible and Latent Cooling with unit’s coil
  • EWT as low as 42° for cooling and up to 180° EWT for heating
  • Up to 1.5 tons of cooling & 2.25 tons of heating per unit
  • Comes standard with a Code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Range: 25 CFM to 203 CFM of O.A. delivered to the space with a single unit
  • Multi-fin diffuser for added performance
  • Airflow characteristics: Up to 20 ft. throw at 100 fpm (ETL Certified)
  • Noise levels: NC24-NC35 (ETL Certified)
  • Drain height as high as 9.5” above ceiling line for gravity draining
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace
  • Uses 1-way blow multi-louver diffuser for improved air distribution

2’x4’ QHS

  • Soffit/Bulkhead Induction Beam
  • 2-Pipe & 4-Pipe with Code Compliant Drain Pan
  • Provides Sensible and Latent Cooling with unit’s coil
  • EWT as low as 42° for cooling and up to 180° EWT for heating
  • Up to 1.5 tons of cooling & 2.45 tons of heating per unit
  • Standard code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Range: 19 CFM to 184 CFM of O.A. delivered to the space with a single unit
  • Multi-fin diffuser for added performance
  • Airflow characteristics: Up to 18 ft. throw at 100 fpm
  • Noise levels: NC25-NC35
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace
  • Uses 1-way blow multi-louver diffuser for improved air distribution

2’x4’ QLU

  • Provides Sensible and Latent Cooling with unit’s coil
  • EWT as low as 42° for cooling and up to 180° EWT for heating
  • Up to 1.3 tons of cooling & 2.1 tons of heating per unit
  • Comes standard with a Code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Range: 17 CFM to 164 CFM of O.A. delivered to the space with a single unit
  • Multi-fin diffuser for added performance
  • Airflow characteristics: Up to 18 ft. throw at 100 fpm (ETL Certified)
  • Noise levels: NC17-NC35 (ETL Certified)
  • Drain height as high as 10.6” above ceiling line for gravity draining
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace
  • Uses 1-way blow multi-louver diffuser for improved air distribution

1’x4’ QLW

  • Provides Sensible and Latent Cooling with unit’s coil
  • EWT as low as 42° for cooling and up to 180° EWT for heating
  • Up to 1.1 tons of cooling & 2 tons of heating per unit
  • Comes standard with a Code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Range: 21 CFM to 102 CFM of O.A. delivered to the space with a single unit
  • Multi-fin diffuser for added performance
  • Airflow characteristics: Up to 20 ft. throw at 100 fpm (ETL Certified)
  • Noise levels: NC24-NC35 (ETL Certified)
  • Drain height as high as 9.7” above ceiling line for gravity draining
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace
  • Uses 1-way blow multi-louver diffuser for improved air distribution

2’x2’ QM1

  • Provides Sensible and Latent Cooling with unit’s coil
  • EWT as low as 42° for cooling and up to 180° EWT for heating
  • Up to .75 tons of cooling & 1.1 tons of heating per unit
  • Comes standard with a Code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Range: 19 CFM to 70 CFM of O.A. delivered to the space with a single unit
  • Multi-fin diffuser for added performance
  • Airflow characteristics: Up to 15 ft. throw at 100 fpm (ETL Certified)
  • Noise levels: NC17-NC33 (ETL Certified)
  • Drain height as high as 10.3” above ceiling line for gravity draining
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace
  • Uses 1-way blow multi-louver diffuser for improved air distribution

2’x2’ Q1 & Q1-L

  • Provides Sensible and Latent Cooling with unit’s coil
  • EWT as low as 42° for cooling and up to 180° EWT for heating
  • Up to .8 tons of cooling & 1.1 tons of heating per unit
  • Comes standard with a Code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Range: 33 CFM to 103 CFM of O.A. delivered to the space with a single unit
  • Multi-fin diffuser for added performance
  • Airflow characteristics: Up to 20 ft. throw at 100 fpm (ETL Certified)
  • Noise levels: NC17-NC35 (ETL Certified)
  • Drain height as high as 10.93” above ceiling line for gravity draining
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace
  • Uses 1-way blow multi-louver diffuser for improved air distribution

QWV (Painted Cabinet Optional)

  • Low Wall/Under window Induction unit & Painted Cabinet
  • 2-Pipe & 4-Pipe with Code Compliant Drain Pan
  • Provides Sensible and Latent Cooling with unit’s coil
  • Standard code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
  • Entering water temperatures as low as 42° cooling and up to 180° for heating
  • Up to 1.8 tons of cooling & 2.9 tons heating per unit
  • Range: 43 CFM to 251 CFM of O.A. delivered to the space with a single unit
  • Airflow characteristics: Up to 18 ft. throw at 100 fpm
  • Noise levels: NC25-NC35
  • ¾” Code Compliant copper FNPT drain connection
  • Vertical Copper Coil
  • Unit has No wiring, no moving parts, no wear parts to replace

Q-Series 1 Way
Gallery