Q-Series
All Way Blow
Q Series units provide a lower first cost option when compared to a traditional sensible only chilled beam system. These Induction Beams can utilize much colder water temperatures for cooling while providing a higher BTU/CFM ratio. Due to this high output it is often that 50% fewer beams are required to meet the room loads vs traditional chilled beams.
Induction Beams enhance the savings and effectiveness of primary air systems. When using Induction Beams, the primary air system, which includes the air handler and the supply and exhaust duct work, can be sized to handle only the required ventilation air. This reduces the size of the equipment and ductwork making it easier to fit into a building space. This also reduces the energy required to supply the ventilation to the building. Induction beams do not require the elaborate controls associated with sensible only Chilled Beam systems.
Lastly Induction Beam systems do not require additional piping loops with heat exchangers, mixing valves, booster pumps and condensate sensors to maintain the water temperature above the dew point of the space, which is required in traditional sensible only Chilled Beam systems.
Q-Series All Way Blow
Q360 All-way Blow 4’x4′
- This unit was designed for densely populated spaces such as classrooms, lecture halls, open floor plan offices and spaces with high ceilings
- Provides Sensible and Latent Cooling with unit’s vertical 360° coil
- EWT as low as 42° for cooling and up to 180° EWT for heating
- Up to 3.25 tons of cooling & 5 tons of heating per unit
- Comes standard with a Code compliant 1 1/2″ deep, internally sloped drain pan with 3/4” FNPT copper connection
- Range: 143 CFM to 476 CFM of Outside Air delivered to the space with a single unit
- Uses an all-way blow 360° multi-louver diffuser for superior air distribution.
- Airflow characteristics: 16 feet throw at 100 fpm in 360° pattern (ETL Certified)
- Noise levels: NC14-NC33 (ETL Certified)
- Drain height as high as 10.4” above ceiling line for gravity draining
- ¾” Code Compliant copper FNPT drain connection
- 360° Vertical Copper Coil
- Unit has No wiring, no moving parts, no wear parts to replace
- 48″x 48″ ceiling grid (2-Pipe & 4-Pipe) with Code Compliant Drain Pan
MINI Q360 All-way Blow 2’x2′
- Provides Sensible and Latent Cooling with unit’s vertical 360° coil
- EWT as low as 42° for cooling and up to 180° EWT for heating
- Up to 1.25 ton of cooling & 2 tons of heating per unit
- Comes standard with a Code Compliant 1 1/2″ Deep, internally sloped drain pan with 3/4” FNPT copper connection
- Range: 45 CFM to 155 CFM of O.A. delivered to the space with a single unit
- Uses an all-way blow 360° multi-louver diffuser for superior air distribution
- Airflow characteristics: 12 feet throw at 100 fpm in 360° pattern (ETL Certified)
- Noise levels: NC14-NC33 (ETL Certified)
- Drain height as high as 10.65” above ceiling line for gravity draining
- ¾” Code Compliant copper FNPT drain connection
- 360° Vertical Copper Coil
- Unit has No wiring, no moving parts, no wear parts to replace
- 2 & 4-Pipe with Code Compliant Drain Pan